Etalon-1 and -2: Array Offset Information
Center of Mass Information:
The standard Etalon center-of-mass correction is 576 mm
correction for
single photon systems
edit level | com (mm) |
---|---|
none | 552 |
3.0 | 556 |
2.5 | 564 |
2.0 | 580 |
correction for
C-SPAD (mm)
FWHM pulse width (ps) |
edit level | ave. num detected photons | |||
---|---|---|---|---|---|
0.1 | 1 | 10 | 100 | ||
1 |
3.0 | 558 | 573 | 608 | 613 |
2.5 | 565 | 581 | 609 | 613 | |
2.0 | 580 | 592 | 610 | 613 | |
100 |
3.0 | 558 | 571 | 600 | 604 |
2.5 | 565 | 578 | 600 | 604 | |
2.0 | 580 | 590 | 601 | 604 |
correction for
leading-edge-half
maximum systems (mm)
FWHM pulse width (ps) | com (mm) |
---|---|
1 | 612 |
100 | 607 |
300 | 598 |
1000 | 578 |
3000 | 562 |
The officially adopted ILRS model for the appropriate CoM correction for the Etalon satellite for any station is provided at http://ilrs.dgfi.tum.de/data_handling/com_etalon.txt.